Bunn CWT -DV User Manual
Page 11

Page 11
36102 090203
TROUBLESHOOTING (cont.)
PROBLEM
Inconsistent beverage level in
dispenser
Consistently low beverage level
in the dispenser
Spitting or excessive steaming
PROBABLE CAUSE
1. Strainer/flow control (.222
GPM)
2. Syphon System
3. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.
4. Water Pressure
1. Timer
2. Strainer/flow Control (.222
GPM)
1. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can
initiate corrosive reactions result-
ing in serious leaks.
REMEDY
(A) Direction of flow arrow must
be pointing towards the brewer.
(B) Remove the strainer/flow con-
trol and check for obstruction.
Clear or replace.
The brewer must be level or slightly
lower in front to syphon properly.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
The water pressure to the brewer
must be at least 20 psi (138 kPa).
Refer to
Service -
Timer for adjust-
ing procedures. See page 27 and
28
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.
Inspect tank assembly for exces-
sive lime deposits. Delime as re-
quired.