Specification summary, Technical specifications, Deltran corporation – Battery Tender 2-Bank International Charger - 12V @ 1-25A (PN 022-0165-DL-WH) User Manual
Page 4
7
burns steady, the charge is complete and the battery can be returned to
service if necessary.
¾ ALTERNATING AMBER & GREEN LIGHTS FLASHING – This is
abnormal and most likely indicates that the battery is sulfated.
STATUS INDICATING SYMBOLS: The following symbols are located
next to the 2 status indicator lights, one amber, one green. There is a
pair of LEDs for each independent output on the 2 & 4 Bank units.
The symbol next to the AMBER light represents a partially
charged battery. The solid band across the bottom is green in
color. The background is yellow. The green area indicates the
charged portion of the battery and the yellow area represents
the uncharged portion.
The symbol next to the GREEN light represents a fully charged
battery. The entire area inside the battery outline is green.
TROUBLESHOOTING CHECK LIST:
1.
NEITHER OF THE CHARGER LIGHTS TURN ON AFTER THE AC POWER
PLUG IS CONNECTED TO THE AC ELECTRICAL OUTLET: Check the
charger AC power plug connection at the AC electrical outlet. Verify that the AC
electrical outlet is functioning properly by plugging in another appliance or a
voltmeter.
2.
THE CHARGER GREEN LIGHT GOES ON IMMEDIATELY WHEN AC
POWER IS APPLIED TO THE CHARGER:
The charger connections at the
battery may be intermittent, the battery may be defective, or the battery might already
be fully charged.
3.
CHARGER IS CHARGING BUT THE GREEN LIGHT DOES NOT TURN ON
IN A REASONABLE AMOUNT OF TIME:
The battery may be large and requires
more time to fully charge than originally expected, there may be another appliance
drawing electric power from the battery while it is charging, or the battery may be
defective. Also, a newly purchased battery may not be fully charged and may take
longer to charge initially.
4.
THE AMBER LIGHT COMES ON AGAIN AFTER THE GREEN LIGHT
CAME ON.
There may be another appliance drawing electric power from the battery
causing its voltage to drop below the reset level. The battery charger then goes back
into full charge mode. Also, the charger connections at the battery may be intermittent
or the battery may be defective.
SPECIFICATION SUMMARY:
Technical Specifications
AC Input Voltage
&
Frequency
100 to 240 VAC, 50/60 Hz
Single 2-Bank 4-Bank
AC Input Current (Maximum)
0.5A 1.0A 2.0A
8
DC Output Voltage
12 Volts
DC Output Current
1.25 Amps, each output.
Specific Charger Output Voltage & Current Amplitudes
throughout the entire charge algorithm, including absorption
and float maintenance, are consistent with the optimum
charging recommendations of major battery manufacturers.
Operating Temperature
-20
°C to +50 °C
Single
2 & 4 Bank
Enclosure Protection Against
Foreign Object & Water Ingress
IP64 IP30
Charger Case Dimensions:
Single: 5.4 in (137 mm) L x 2.9 in (74 mm) W x1.6 in (41 mm) H.
2-Bank: 8.8 in (224 mm) L x 4.8 in (122 mm) W x 3.5 in (89 mm) H
4-Bank:
8.8 in (224 mm) L x 7.0 in (178 mm) W x 3.5 in (89 mm) H
Note: For all models, allow an additional 2 in (50.8 mm) on each end
of the length dimension for safe bend of AC and DC power cord strain
relief. Also, on the 2 & 4-Bank only, add an additional 2 in (50.8
mm) to the width dimension to account for the mounting pads.
Shipping Weight:
Single: Approx. 2.5 lbs (1.2 kg)
2-Bank: Approx. 4 lbs (1.8 kg)
4-Bank: Approx. 5 lbs (2.3 kg)
WITH:
Accessories &
Retail Packaging
Acceptable Battery Cell Type, Number, and Ah Capacity
(Typical usage: recharge from 50% discharge)
Charger Output Cell Type
Number
Ah Capacity
12V, 1.25 Amp
Lead Acid
Only
6 Cells
Up to 95 Ah