Caution, Electrical connection – Bosch T20-UL User Manual
Page 8
8
Electrical connection
d
CAUTION
d
Power cord must be connected
by a qualified person only.
Connect to individual Brunch
Circuit.
Do not use an adapter.
Do not use an extension cord.
Do not remove ground prong.
For CANADA
Your dryer comes with a power
supply cord, CSA listed in Canada.
The Bosch dryer requires a 4Ćwire
receptacle.
When installing the receptacle for
the dryer cord, ensure that the
power supply cord is accessible
when the dryer is in the installed
position.
The power cord should only be
replaced by a qualified person.
Use a 4Ćwire power supply cord
(see electrical connection U.S.A.
below).
For U.S.A.
Your dryer comes without a power
supply cord.
The power cord must
meet the following requirements:
-
UL listed in the USA
-
208 ć 240 volt rated (minimum)
-
30 amps
-
Type SRDT or DRT (UL 2158)
-
Five feet long (minimum)
-
suitable for dryer
d
CAUTION
d
Power cord must be connected
by a licensed electrician only.
Use only a U.L. approved
30 amp power cord with strain
relief clamp -
note manufacturer's instructions.
Do not plug end of power cord
into a live receptacle before conĆ
necting power cord to appliance
terminals and closing junction/
splitter box as described below.
Do not reuse old power cord.
Cord must have closed loop or
upturned end wire terminating
connectors.
Do not make a sharp bend or
crimp wiring/conductor at conĆ
nections.
Only a 4Ćconductor cord shall
be used when the appliance is
installed in a mobile home, in a
recreational vehicle, in a new
branch circuit installation or an
area where the local codes do
not permit grounding through
the neutral.
The splitting box is located at the
top rear of the appliance.
To connect the power cord you
have to remove the cover plate.
1. Remove the screws of the
cover plate on the rear side of
the appliance.
2. Push the cover plate from the
front to the rear side and lift up.
3. Open the splitting box in the
right corner (20 Torx).
4. Loosen the strain relief in the
appliance.
5. Thread the power cord through
the U.L. strain relief clamp.
6. Tighten the screws (2.5 Nm) of
the U.L. strain relief clamp so
that the power cord cannot be
moved.
7. Connect the power cord as
described below.
8. After connecting the power
cord close the splitting box and
replace the cover plate fasten in
place with reverse handling.
Dryer supplied to customer
Connecting 4Ćwire power supply
cord
1. Remove the screws from the
cover of the terminal block.
2. Remove the screws from the
grounding cable.
3. Remove the grounding cable.
4. Loosen the 2 screws labeled L
in the terminal block.
5. Attach the power cord ground
conductor (green) to the
GROUND point. Tighten the
screw (2.5 Nm) so that the
ground conductor is held
securely in place.
6. Attach the 2 power cord outer
conductors (red and black) to
the 2 terminals labeled L and
the remaining power cord
conductor (white) to the
terminal labeled N.