1.

Make sure installation area is clean before starting.

2.

If the permanent air supply work is not complete, some means of temporary lines
with an on-off device for the air supply should be set up for testing purposes.

3.

Place the lift in the installation area.

CAUTION!

When moving the lift do not attempt to pick it up by the platform;
it is hinged and could be damaged. Pick up from under the base
frame ONLY.

4.

Make temporary air connections. Raise the lift to the top of its travel and make
positioning adjustments. Check for the proper height. If needed, shim to the
desired height.

WARNING!

Block scissors mechanism in the raised position prior to
working under lift. See the “Lift Blocking Instructions” section.

5.

If the decision is made to lag the lift to the floor, the base frame of the lift has pre-
drilled holes for lagging the lift. Mark the holes, drill, and install with anchors.

6.

Make permanent air connections and operate the lift through a few cycles.

7.

Clean up any debris from the area. A clean installation makes a good impression
and creates a much safer environment!

WARNING!

A l l

D A N G E R ,

WARNING, and CAUTION labels

and informational decals and plates must be intact and in place on the
lift. Contact an Autoquip representative if labels are missing or
damaged. See the “Label Identification” section.

INSTALLATION INSTRUCTIONS