Figure 18 – gate interlock limit switch location, A" view "a-a, Item #1 detail – Autoquip CAROUSEL WORK PLATFORM User Manual
Page 31: Mounting bracket location detail, 1) required per lift
31
ANGLES:
+/- 1/32
.X +/- .1
.XX +/- .03
.XXX +/- .010
+/- 1/2~
BREAK ALL SHARP EDGES:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
FRACTIONS:
DECIMALS:
ONE PLACE
TWO PLACE
THREE PLACE
.010 MAX. x 45~ CHAMFER
(1) REQUIRED PER LIFT
ITEM #1 DETAIL
NOTE:
THIS EDGE TO BE WELDED
TO UNDERNEATH SIDE OF
PLATFORM.
MOUNTING BRACKET LOCATION DETAIL
UNDERSIDE OF
PLATFORM (REF.)
PLATFORM DRAWING.
7/16" HOLE DRILLED IN
PLATFORM AT LOCATION
OF LOCKING PIN. SEE
(4) #10-24 TAPPED HOLES.
PLATFORM (REF.)
UNDERSIDE OF
7/16"
3"
3"
19/32"
2-11/32"
3-1/2"
2-1/2"
3" (REF.)
LIMIT SWITCH TO BE MOUNTED UNDER PLATFORM
BE WIRED NORMALLY OPEN HELD CLOSED (BY THE
1.
2.
ITEMS #6 THRU #9 NOT SHOWN.
TO SENSE THE GATE LOCKING PIN. SWITCH TO
NOT SHOWN IN THIS
VIEW FOR CLARITY.
ITEMS #2 THRU #9
OR PLATFORM.
PIN) AND WIRED TO THE J-BOX ON THE LEG
1
2
3
4
5
1
SIZE
NO.
REVISIONS
BY
DATE
<2T
AQJ NO.
1 of 1
C
REV.
DRAWING NUMBER:
4
6
351-0192-2
6
2
3
1
5
and cannot be used for
REFERENCE DWG.
DATE:
PAGE:
DRAWING TITLE
JOB NAME:
APPROXIMATE WEIGHT:
C
property of Autoquip Corp.
of Autoquip Corp.
without permission
design & construction
This drawing is the sole
1997
1/8"
1/8"
"A"
"A"
VIEW "A-A"
Figure 18 – Gate Interlock Limit Switch Location