beautypg.com

Installation – APG FLX user manual User Manual

Page 5

background image

Rev. C4, 10/09

FLX Series

5

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Installation

- Unpacking -

When unpacking the instrument, exercise care not to subject the instrument to
mechanical shock. After unpacking, visually inspect the instrument for
damage.

- Environment -

The FLX series sensors should be installed indoors or outdoors in an area
which meets the following conditions:

1. The ambient temperature does not exceed -40

0

F to +185

0

F (-40

0

C to 85

0

C).

NOTE: It is recommended that a sun shield be installed over the housing if
exposed to direct sunlight.
2. The medium temperature does not exceed -40

0

F to +185

0

F (-40

0

C to

85

0

C).

3. Relative humidity up to 100%
4. Pollution Degree 2
5. Measurment Category II
6. Altitude 2000 m or less.
7. Locate the sensor away from strong magnetic fields such as those
produced by motors, transformers, solenoid valves, etc.
8. The medium is free from metallic substances and other foreign matter.
9. No corrosive gases such as NH

3

, SO

2

, Cl

2

, etc.

10. No excessive vibration
11. Ample space for maintenance and inspection.