• Circuit Protection

WARNING!

DO NOT EXCEED CONTACT RATINGS! When an inductive load is
used (e.g. a motor, a coil, or an electromagnetic relay), a back
electromotive force of several hundred volts (energy stored in the
inductance) arises when the contacts are opened. This results in
considerable decrease in contact life. The same result arises even
when a resistive load is used with a high voltage or a large current. The
figures below show circuits for protecting the reed switch(s) from the
back electromotive force.

L

C

R

E

C = I

R = Approx.

10 x I (I + 50/E)

E

Protecting Circuit Using CR

Protecting Circuit Using Varistor

Protecting Circuit Using Diode

2

/10 (uF)

Switch

Code A

Code B

Max. contact capacity

20 VA

50 VA

Max. switching current

0.5A AC

0.5 A AC

Max. Voltage

220 VAC

220 VAC