Iru-2000 specifications – APG IRU-2000 datasheet User Manual
Page 2

IRU-2000 Specifications
Performance
• Operating Range
1 - 25 ft. (0.30 - 7.62 m) for liquids
1 - 10 ft. (0.30 - 3.05 m) for solids
• Beam Pattern: 9º off axis
• Internal Temperature Compensation
• Frequency: 69 kHz
• Accuracy: ±0.25% of detected range
• Resolution: 0.1 in. (2.5 mm)
• Response Time: Up to 50 Hz, or once every 20 ms
Connectivity
Output:
• 1 Solid State Relay
• Isolated 4-20 mA
• RS-485 with (1) NPN trip point
• 4-20 mA with (2) NPN trip points
Environmental
• Ratings: NEMA 4X
• Operating Temp: -40º - 140ºF (-40º - 60ºC)
Electrical
• Total Current Draw: 80 mA @ 24 VDC
• Supply Voltage: 12 - 28 VDC
• Wiring Connections:
IRU-2002 & 2003 - 6 pin terminal strip
IRU-2004 & 2005 -
- 6 conductor shielded cable
(6 ft standard length)
- Optional 5 pin micro-connector
Programming
• Interface with RST-3001/3002 Programmer
(purchase separately)
-The RST-3001 is 32 bit only
-The RST-3002 is 64 bit compatible
• User selected units of measure
Physical
• ABS with UV Inhibitor
• Surface Mount with 4 screws
Certification
• CSA General Purpose
Automation Products Group, Inc.
www.apgsensors.com
tel. 888.525.7300
2
1.63”
41.4 mm
3.25”
82.6 mm
5.74”
145.79 mm
3.25”
82.6 mm
2.50”
63.5 mm
3.60”
91.4 mm