beautypg.com

Wiring the logic outputs, Pl-8 inputs, Outputs – Allen&Heath PL-8 User Manual

Page 4: Specification, In/out connectors, Switch inputs, Logic outputs, Communication, Configuration, Power supply

background image

4

PL-8 User Guide AP5270 issue 3

Wiring the logic outputs

The 7way output terminal block

provides four logic output connections. Pins 5 to 7 ‘G’ are used as the
common return ground. One wire can feed this ground to a bank of indicators
or other devices.

The output works by switching the internal +5V reference supply through a 470
ohm resistor to the pin. This presents a positive voltage when the output is
turned on, and an open circuit when it is turned off. The switching is done
using a transistor. The resistor limits the current to a maximum 10mA to ensure
the connected equipment does not draw more than the PL-8 can provide.

The output may be used in many ways to satisfy a range of interfacing
applications. It is important that the installer has a good working knowledge of
interfacing circuits. Incorrect application may result in damage to the
equipment. Typical applications include powering an LED indicator and
switching solid state (low current) relays.

This product complies with the European Electromagnetic
Compatibility directives 89/336/EEC & 92/31/EEC.

NOTE: Any changes or modifications to the equipment not approved by Allen
& Heath could void the compliance of the equipment. Whilst we believe the
information in this guide to be reliable we do not assume responsibility for
inaccuracies. We also reserve the right to make changes in the interest of
further product development.

Copyright© 2005 Allen & Heath Ltd. All rights reserved.

1K5

CONTROL

CHAIN

OPTO-ISOLATED SWITCH INPUTS

LOGIC OUTPUTS

PL-8

INPUTS

PL-Anet OUT

PL-Anet IN

OUTPUTS

LED INDICATOR

RELAYS

+

-

LAMPS

MOTORS

EQUIPMENT

DEVICE

+20V

+5V

G

G

To next PL-Anet device

or terminator

From iDR or previous

PL-Anet device

SWITCH

SWITCH

SWITCH

SWITCH

SOLID STATE

1 2 3 4 G

G

2 3 4

1

470R SERIES RESISTOR

G

G

LED INDICATOR

G

470R

+5V

INTERNAL PL-8 CIRCUIT

(1 OF 4 SHOWN)

SERIES RESISTOR

TYPICALLY 6mA

2 3 4 G

G

1

Specification

In/Out Connectors:

Phoenix 7way screw terminal blocks
For permanent bare wire connection

Switch Inputs:

4x opto-isolated switch closure inputs
+5V DC through series 1k5 ohm resistor
Switch closure connects pin to ground
Maximum current when switched = 1.2mA
Maximum switch+cable resistance = 1k ohm
Switch types:

Momentary action

Microswitch

Relay contact

Custom

interface

Logic Outputs:

4x transistor logic outputs
Uses internal PL-Anet supply
ON = +5V DC through series 470 ohm resistor
OFF = open circuit
Output voltage depends on current drawn
Maximum current per output (shorted) = 10mA
Output capability:

LED indicator

Solid state relay

Custom

interface

Communication:

RS485 based PL-Anet serial port
RJ45 input and output connectors
Maximium 15x addresses per PL-Anet branch

Configuration:

iDR System Manager software V3.1 or greater
Refer to the software Help file
Separately configure switches and outputs
Input switch function: Volume up/down

Mute on/off

Patch

recall

Monitor select

Logic output function: Static on/off

Mute status

Soft switched

Patch

recalls

Scheduled events

Power Supply:

Internal +5V DC from PL-Anet 20V supply
Minimum PL-Anet voltage at PL-8 = 11V
Maximum logic output = 40mA (all shorted)