Step 8 – Aladdin Light Lift ALL300RM-CM(Two Circuit Fixtures Only) User Manual
Page 7
STEP 8
Turn off supply power before wiring ALL300RM motor switch. Turn off motor switch in square box. Wire
motor switch with 110V wiring. The 110V motor feed must be kept separate from 110V light switch leg.
Keep motor and light neutrals separate. Motor neutral is white and 14 gauge. Only wire motor switch at
this time. See Diagram G.
Never wire the ALL300RM improperly. Make sure electricity is turned off when installing and/or
performing maintenance on the ALL300RM. Improper wiring and/or electricity could cause death,
personal injury, and/or property damage.
Do Not Wire Light
Switch At This Time
10 awg
Light Neutral
14 awg
Motor Neutral
14 awg
Motor Hot
110V Incoming
Hot For Motor
Diagram G
Black
12 awg
Light Hot
Circuit 1
Red
12 awg
Light Hot
Circuit 2