STEP 25
Turn off supply power before wiring ALL300RM. Turn off light switch in square box. Wire light switch
with 110V wiring. The 110V light switch leg can not be used as motor feed. Keep light and motor neutrals
separate. The light neutral is white and 10 gauge. If wired properly, a dimmer may be used. See Diagram O.
Wire Light Circuits on seperate phases (2 hots - 1 neutral).
Never wire the ALL300RM improperly. Make sure electricity is turned off when installing and/or
performing maintenance on the ALL300RM. Improper wiring and/or electricity could cause death,
personal injury, and/or property damage.
10 awg
Light Neutral
14 awg
Motor Neutral
14 awg
Motor Hot
110V Incoming
Hot For Motor
110V
Incoming
Hot for Light
Circuit 1
Diagram O
110V
Incoming
Hot for Light
Circuit 2
Black
12 awg
Light Hot
Circuit 1
Red
12 awg
Light Hot
Circuit 2