WEP Wireless Security
Figure 9: WEP
Data - WEP Screen
WEP Data Encryption
Authentication
Type
Normally, this should be left at the default value of "Automatic".
If changed to "Open System" or "Shared Key", ensure that your
Wireless Stations use the same setting.
WEP Data
Encryption
Select the desired option, and ensure the Wireless Stations use
the same setting.
• 64 Bit - data is encrypted, using the default key, before
being transmitted. You must enter at least the default key.
For 64 Bit Encryption, the key size is 10 chars in HEX (0~9
and A~F).
• 128 Bit - data is encrypted, using the default key, before
being transmitted. You must enter at least the default key.
For 128 Bit Encryption, the key size is 26 chars in HEX (0~9
and A~F).
Key
Select the key you wish to be the default. Transmitted data is
ALWAYS encrypted using the Default Key; the other Keys are
for decryption only.
You must enter a Key Value for the Default Key.
Key Value
Enter the key value or values you wish to use. The Key is re-
quired, the other keys are optional. Other stations must have the
same key.
Passphrase
If desired, you can generate a key from a phrase, instead of
entering the key value directly. Enter the desired phrase, and
click the "Generate Keys" button.
AirLive WN-301R User’s Manual
25