8 lpt1 parallel interface, 9 optional usb connection on the faceplate, 10 external drives – ADS-TEC OPC5115 User Manual
Page 22: Industrial pcs opc5115
Industrial PCs OPC5115
22
© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen
8.8
LPT1
PARALLEL INTERFACE
The LPT interface is a parallel Centronics interface, which can be used to connect a printer.
PIN
NUMBER
SIGNAL
NAME
1
STROBE
2
Data 0
3
Data 1
4
Data 2
5
Data 3
6
Data 4
7
Data 5
8
Data 6
9
Data 7
10
-ACK
11
Busy
12
Paper Empty
13
Print select
14
-Auto Form Feed
15
-ERROR
16
-Initialize
17
-Printer Select In
18
GND
19
GND
20
GND
21
GND
22
GND
23
GND
24
GND
25
GND
8.9
O
PTIONAL
USB
CONNECTION ON THE FACEPLATE
A USB interface can optionally be accessible from the front. The interface is found under a
plastic cover to the right under the display. The cover has a tab on the right side, which
can be used to open it. The plastic cover is to be closed carefully after having used the
USB interface, because otherwise the protection class IP65 is not ensured on the front.
8.10
E
XTERNAL DRIVES
There are no CD/floppy drives installed in the standard models of the device. However, the
system has a USB interface which can be used to connect an external drive. The devices
used for this purpose should always be suitable for industrial environments.
Warning:
It is not permissible to connect or disconnect an external drive while the device is
running, because it can not be ruled out that the drive is in use at this time. Non-
adherence can cause loss of data!