beautypg.com

10 pto lubrication, Important, 50 h – Echo CH5540 Owners Manual v.1 User Manual

Page 19: English

background image

5 INCH PTO CHIPPER

15

ENGLISH

SERVICE & MAINTENANCE

WARNING

BEFORE INSPECTING OR SERVICING ANY PART OF THIS MACHINE, SHUT OFF POWER SOURCE AND MAKE SURE

ALL MOVING PARTS HAVE COME TO A COMPLETE STOP.

5.10 pTo luBrICaTIon

Figure 5.8. PTO lubrication

Figure. 5.7. Grease zerks on CH5540

8

h

8

h

8

h

8

h

8

h

ImporTanT

Polyurea and lithium-based greases are not compatible.

Mixing the two grease types may lead to premature failure.

Do not over grease bearings. Overfilling can lead to

excessive heat and/or unseating of the seals. Add

grease slowly and under light pressure. Whenever

possible, rotate bearing slowly while lubricating.

noTe

1. Every 8 hours, lubricate PTO cross journals. Make sure

grease purges through all four bearings.

2. Every 8 hours, lubricate PTO inner tubes. Telescoping

members must have lubrication to operate successfully.

Telescoping members without fittings should be pulled apart

and grease should be added manually with a brush.

3. Every 8 hours, lubricate the PTO shield retaining bearing.

Molded nipples on the guard near each guard bearing are

intended as grease fittings and should be lubricated every

8 hours of operation.

50

h