5.10 pTo luBrICaTIon
Figure 5.8. PTO lubrication
Figure. 5.7. Grease zerks on CH5540
8
h
8
h
8
h
8
h
8
h
ImporTanT
Polyurea and lithium-based greases are not compatible.
Mixing the two grease types may lead to premature failure.
Do not over grease bearings. Overfilling can lead to
excessive heat and/or unseating of the seals. Add
grease slowly and under light pressure. Whenever
possible, rotate bearing slowly while lubricating.
noTe
1. Every 8 hours, lubricate PTO cross journals. Make sure
grease purges through all four bearings.
2. Every 8 hours, lubricate PTO inner tubes. Telescoping
members must have lubrication to operate successfully.
Telescoping members without fittings should be pulled apart
and grease should be added manually with a brush.
3. Every 8 hours, lubricate the PTO shield retaining bearing.
Molded nipples on the guard near each guard bearing are
intended as grease fittings and should be lubricated every
8 hours of operation.
50