6 INCH CHIPPER

14

SERVICE & MAINTENANCE

BEFORE INSPECTINg OR SERVICINg ANy PART OF THIS MACHINE, SHuT OFF POWER SOuRCE,

AND MAKE SuRE All MOVINg PARTS HAVE COME TO A COMPlETE STOP.

WaRNING

Rotor Housing

Chipper Anvil

Spacer

Figure 5.2, Chipping anvil bolts

5.6 adJuSTING/REpLacING dRIvE bELT

Check the condition of the drive belt annually or after ev-

ery 25 hours of operating, whichever comes first. If the

belt is cracked, frayed, or worn, replace it. To replace or

adjust drive belt, proceed as follows:

Shut off engine and disconnect spark plugs.

1.

Remove belt guard.

2.

Remove the hydraulic pump belt by loosening the bolts

3.

on the hydraulic pump (for hydraulic feed units only).
Take the tension off the drive belt by depressing the

4.

belt engagement pedal, loosening the engine bolts,

and sliding the engine back. Then, remove the drive

belt from pulleys.
Install the new belt on pulleys. Slide engine back into

5.

place and tighten bolts to proper torque.
Check pulley alignment with a straight edge and adjust

6.

if needed.
Check belt tension and adjust if needed. The belt

7.

deflection at the center of the belt should be 7/16"

when a 20 lb. load is placed against the belt (see

Figure 5.4).
Replace hydraulic pump and hydraulic pump belt.

8.

Replace belt guard.

9.

depress belt engagement pedal, start engine, engage

10.

drive belt, and test unit. Readjust pulleys and belt

tension if needed.

Figure 5.3, Chipper pulley system

5.5 SETTING bLadE cLEaRaNcE

1. lift rotor access cover and expose rotor. loosen the

three 1/2 inch bolts that hold the chipper anvil to the

frame.

2. Measure the amount of clearance between chipping

blade and chipping anvil from inside of housing.

3. Adjust inward or outward to desired measurement.
4. Tighten bolts on chipping anvil to 75 ft-lbs. and resume

operation.

If the chipping anvil edge is damaged or worn unevenly,

remove the three bolts holding the anvil and use one of

the other three edges. Adjust for correct measurement.

The chipping blades should clear the anvil by 1/16 inch to

1/8 inch. Check the clearance every 8 hours of operation

and adjust if needed. The chipping anvil is reversible. All

four sides of the anvil can be used for chipping.
To adjust the anvil:

WaRNING

It is important to ensure that the minimum gap between

the chipping anvil and All chipping blades is 1/16”. All

chipping blades should be rotated until even with the

chipping anvil and then measured. Failure to do so

can result in the chipping blades striking the chipping

anvil, causing serious injury or death.