beautypg.com

Install blower pipes, Assembly pb-500 h/t – Echo PB-500T User Manual

Page 16

background image

16

X7505200007

© 02/2014 ECHO Inc.

ASSEMBLY

PB-500 H/T

Note: Blower use will eventually loosen pipe connections.

Exclusive positive locking system allows pipes to be
tightened. If loosening occurs, remove two straight pipes
and install according to instructions 7 & 8.

PB-500T

Never perform maintenance or assembly procedures with engine running or serious personal injury
may result.

Install Blower Pipes

1. Place guide loop (G) across clamp, and turn until clip fully

engages clamp band.

Note: Clamp with cable guide loop (G) fits elbow end of flexible

pipe (B).

2. Assemble clamps (A) onto both ends of flexible pipe (B).

3. Assemble flexible pipe (B) to elbow (D) on blower. Position

guide loop (G) on inside (blower side) of flexible tube and
tighten clamp (A).

Note: A light lubricant may be used to ease assembly of flexible

pipe to blower elbow.

Note: Hang handle freely from blower to assure throttle cable is not twisted before installing handle (E).

4. Position cable between the elbow (D) and frame and along

the top of the flexible pipe. Loosen knob (H) on handle (E).
Align notch in handle with tabs (F). Install onto swivel pipe
(C) past long ridges in pipe.

5. Assemble swivel pipe (C) into flexible pipe (B) and tighten

clamp (A).

6. Clip throttle cable into throttle cable guide loop (G).

For more information
scan this QR code.

G

G

A

G

B

A

E

H

F

C

D

A

A

B

G