Starting warm engine, Stopping engine, Operation pb-760 ln h/t starting warm engine – Echo PB-760LNT User Manual

Page 20

background image

20

X7531125002

© 03/2013 ECHO Inc.

OPERATION

PB-760 LN H/T

Starting Warm Engine

The starting procedure is the same as Cold Start except DO
NOT close the choke.

- PB-760 LN H

1. Throttle Lever

Move throttle position lever (A) to IDLE DETENT positions.

- PB-760 LN T

1. Throttle Position / Stop Switch Button

Slide Throttle Position / Stop Switch Button (A) back to idle
position.

- PB-760 LN H and T

2. Purge Bulb

Pump purge bulb (D) until fuel is visible. Pump bulb an
additional 4 or 5 times.

3. Recoil Starter

Pull recoil starter handle (E) and engine should start. Do not
use choke (C)

Note: If engine does not start after 5 pulls, use cold start

procedures.

Stopping Engine

- PB-760 LN H

1. Throttle Lever

Move throttle lever (A) to IDLE DETENT position and allow
engine to return to idle before shutting off engine.

2. Throttle Lever

Move throttle lever (A) to "O" (Stop) position.

- PB-760 LN T

1. Throttle Position / Stop Switch Button

Release throttle trigger. Move Throttle Position / Stop Switch Button (A) forward to idle position and allow
engine to return to idle before shutting off engine.

2. Throttle Position / Stop Switch Button

Move Throttle Position / Stop Switch Button (A) all the way forward to STOP position.

If engine does not stop when stop switch is moved to STOP position, close choke - COLD START
position - to stall engine. Have your ECHO dealer repair stop switch before using blower again.

PB-760 LN H

PB-760 LN T

A

C

E

D

PB-760 LN H

PB-760 LN T

A

This manual is related to the following products: