beautypg.com

General information – Beckett CF375 User Manual

Page 3

background image

3

CF375 Burner Manual

Agency approvals

UL listed to comply with ANSI/UL296 and certifi ed to
CSA B140.0.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and must be
specifi ed at time of order.


Specifi cations

Fuels

DO NOT USE GASOLINE,
CRANKCASE OIL, OR
ANY OIL CONTAINING
GASOLINE

U.S. #1 or #2 Fuel Oil only
(ASTM D396)
Canada #1 Stove Oil or #2
Furnace Oil only

Firing range

1.65 to 3.75 GPH

Motor

1/7 HP 3450 RPM
120/60 hz standard
1.7 amps @ 120 VAC

Ignition Trans.

120V/12,000V

Housing

Cast aluminum

Fuel unit

100 - 200 PSIG

Oil nozzle

45° - 70° solid

Shipping wt.

25 lbs.

General Information

Section: General Information

Hazard Defi nitions

Within the boundaries of the hazard warning, there will
be information presented describing consequences if the
warning is not heeded and instructions on how to avoid
the hazard.

Indicates a hazardous situation,
which, if not avoided, will result

in death or serious injury.

Indicates a hazardous situation,
which, if not avoided, could

result in death or serious injury.

Indicates a hazardous situation,
which, if not avoided, could

result in minor or moderate injury.

Intended to bring special attention
to information, but not related to

personal injury or property damage.

THE INSTALLATION OF
A BURNER SHALL BE IN

ACCORDANCE WITH THE REGULATIONS OF
AUTHORITIES HAVING JURISDICTION