SECTION 3 - TROUBLESHOOTING
3120768
– JLGSizzor –
3-3
Platform raises or lowers erratically
Enable switch not activated
Activate enable switch
Function not activated within 3 seconds after
enable switch was depressed
Reactivate enable switch
Enable switch not functioning properly
replace enable switch circuit card
Hydraulic system low
replenish oil as necessary
Restricted or broken hydraulic line or fitting
Clean, repair or replace as necessary
Control valve not functioning properly
Repair or replace valve
Worn seals in lift cylinder
Replace seals
Cylinder not functioning properly
Repair or replace cylinder
Platform drifts down
Worn seals in lift cylinder
Replace seals
Manual descent valve open
Close manual descent valve
High drive does not operate below horizontal
Damaged wiring on limit switch
Repair or replace wiring
Damaged limit switch
Replace limit switch
Table 3-1. Platform Assembly Troubleshooting
TROUBLE
PROBABLE CAUSE
REMEDY