JLG 1200SJP Operator Manual User Manual
Page 110

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6-18
– JLG Lift –
3121141
NOTE:
After S/N 0300134389 machines may be built with either Bonfigli-
oli or Reggiana Riduttori wheel drive hubs.
4.
A. Wheel Drive Hub (Prior to S/N 100131)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 liters (1/2 full)
Lube - EPGL
Interval - Change after first 150 hours then every 1200
hours of operation
B: Wheel Drive Hub (S/N 100131 to Present)
Lube Point(s) - Level/Fill Plug
Capacity - 2.1 quarts (2 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o’clock position and Check
port at 8 o’clock position. Pour lubricant into fill port until it
just starts to flow out of check port.