Setting menu parameters – IKA ULTRA-TURRAX Tube Drive control User Manual
Page 22

22
UTTD_c_022014
Setting menu parameters
The device can be operated in mode A, B and P1 to P9. The mode set-
ting will be stored automatically when operation is over, or the device
is switched off. User may change the mode setting in the main menu
if necessary.
• Operation mode A
In this mode, when current operation is over or the device is switched
off, all working settings will not be stored.
• Operation mode B
In this mode, when current operation is over or the device is switched
off, all menu and working settings will be stored.
• Operation mode P1 - P9
In mode P1-P9, the user can set and save required parameters,
(target speed, timer value and rev value) in program. The parameter
settings can only be changed in the menu program. These settings can
also be used directly when necessary.
If the timer value in the program setting is more than 3 minutes, the
speed upper limit is 4000 rpm.
If the timer is not activated in the program and speed is higher than
4000 rpm, the speed will also decrease to 4000 rpm after running 3
minutes.
• Setting operation mode between A and B
Press the “Menu/Back” button (C) in the main menu.
Turn the “Rotating/Pressing” knob (B) to select the “mode” item in
the main menu.
Press the “Rotating/Pressing” knob (B).
Turn the “Rotating/Pressing” knob (B) to select mode A or B in submenu.
Press the “Rotating/Pressing” knob (B) again to complete the
process.
Press the “Menu/Back” button (C) to return to the working screen.
11
Operation mode
11.1
• Setting operation mode between P1 and P9
Press the “Menu/Back” button (C) in the main menu.
Turn the “Rotating/Pressing” knob (B) to select the “mode” item
in the main menu.
Press the “Rotating/Pressing” knob (B).
Turn the “Rotating/Pressing” knob (B) to select the “mode” item
in mode P1 and P9 in submenu.
Press the “Rotating/Pressing” knob (B) and enter desired menu
program.
Turn the “Rotating/Pressing” knob (B) to select desired program
item.
Press the “Rotating/Pressing” knob (B) .
Turn the “Rotating/Pressing” knob (B) to change the value.
Press the “Rotating/Pressing” knob (B) again to complete the
setting.
Press the “Menu/back” button (C) to complete the process,
display will return to working screen.
Note: The target speed and timer value in the program should be
less than “rpm max” and “timer max” setting in menu. Otherwise,
the device will run according to the setting in the menu.
Operation language
11.2
The language can be set to: English, German, Chinese, French,
Spanish, Italian and Korean. The language setting will be stored au-
tomatically when operation is over or the device is switched off.User
can change the language setting in the main menu if necessary.
• Setting operation language
Press the “Menu/Back” button (C) in the main menu.
Turn the “Rotating/Pressing” knob (B) to select the “language”
item in the main menu.
Press the “Rotating/Pressing” knob (B) to confirm “language”.
Turn the “Rotating/Pressing” knob (B) to select a language.