Chapter 6. controls, Battery disconnect switch 6-1, Lower controls 6-1 – Snorkel TB37 2001 User Manual
Page 20: Start switch 6-1, Emergency stop switch 6-1, Controls switch 6-1, Ground controls switch 6-1, Disconnect switch, 6-1, 7-5, 8-2, 9-1, 10-1, Control selector switch, 6-1, 8-2, Lower controls start switch, 6-1, 8-2

Chapter 6. Controls
Controls to position the platform are located on the lower
control panel on the turntable and on the upper control
panel in the platform. Drive controls are located on the
upper control panel only.
Battery Disconnect Switch
The battery disconnect is located behind the door on
the right side of the turntable above the battery (refer to
Figure 6.1).
Figure 6.1—Battery Disconnect Switch
The battery disconnect removes electrical power from
all electrically controlled functions when in the off posi-
tion. Place the switch in the on position to electrically
connect the battery to the electrical system.
Only authorized personnel should operate the
aerial platform. Unqualified personnel may cause
injury to coworkers or property damage. Lock the
battery disconnect switch in the off position before
leaving the aerial platform unattended.
Turn the battery disconnect switch off to prevent unau-
thorized use of the aerial platform.
Lower Controls
The lower controls (refer to Figure 6.2) are located on
the left side of the turntable. Boom and platform func-
tions can be operated from the lower controls. The fol-
lowing are located on the lower control panel.
●
Start switch
●
Emergency stop switch
●
Controls switch
●
Ground controls switch
●
Rotation switch
●
Boom elevation switch
●
Top boom switch
●
Boom switch
●
Platform level switch
●
Platform rotator switch
●
Engine/emergency power switch
●
Throttle switch
●
Fuel switch
Figure 6.2—Lower Controls
Start Switch
The start switch works like an automobile ignition
switch. Hold it at start until the engine starts, then re-
lease it to on. If the engine dies, the key must be turned
to off before it will go back to start.
An alarm sounds when the switch is turned on to warn
others that the machine engine is being started.
Emergency Stop Switch
The emergency stop is a two-position toggle switch with
a red safety guard. Push the red safety guard down over
the toggle switch to disconnect power to all control cir-
cuits. Lift the guard and push the toggle switch up to the
on position to restore power.
Controls Switch
Use the controls switch to select between lower control
and upper control operation. Place the switch in the plat-
form position to operate the aerial platform from the up-
per controls and in the ground position for lower controls
operation.
Ground Controls Switch
Hold the switch in the on position to operate the ma-
chine from the lower controls.
This switch is spring returned to the off position.
TB37 – 0172094
page 6 - 1
CAUTION