Service Technicians
Include the following when inspecting the machine.
Daily Prestart Inspection
Item
Inspect For
Lift Cylinder Coils
Make sure the coils are in good condition and are not swollen or split
Solenoid Wire Harness
Make sure the wires are in good condition and the connection to the coils are properly
made and are clean, without corrosion
Frequent Inspection and Maintenance – Every 90 Days or 150 Hours
Item
Inspect For
Engine Alternator Voltage
Verify voltage reading at B terminal on the alternator is between 13.8 and 14.2 volts
Solenoid Wire Harness
Make sure the coils are in good condition and are not swollen or split
Machine Operators
Include the following when inspecting the machine and observe proper machine operation when lowering the platform.
Daily Prestart Inspection
Item
Inspect For
Lift Cylinder Coils
Make sure the coils are in good condition and are not swollen or split
Solenoid Wire Harness
Make sure the wires are in good condition and the connection to the coils are properly
made and are clean, without corrosion
Lowering the Platform
When lowering the platform make sure to have the engine running.
If the engine will not run but the battery is properly charged, at the lower controls, turn the key switch to the On position and
pull the emergency stop button outward. At the upper controls, turn the start switch to the On position and pull the emergency
stop button outward.
If the engine will not run and the battery will not supply ample power, 12 volts can be jumped from another source to each of
the coils to allow the platform to be lowered.