background image

Page 10

Operation Manual

Maintenance

B

A T T E R Y

M

A I N T E N A N C E

Figure 6:

Access to Batteries

W A R N I N G

!

!

Hazard of explosive gas mixture. Keep sparks, flame,
and smoking material away from batteries.

Always wear safety glasses when working near
batteries.

Battery fluid is highly corrosive. Thoroughly rinse away
any spilled fluid with clean water.

Always replace batteries with Snorkel batteries or
manufacturer approved replacements weighing 26,3 kg
(58 lbs.) each.

• Check the battery fluid level daily, especially if the

machine is being used in a warm, dry climate.

• If electrolyte level is lower than 10 mm (

3

/

8

in.) above the plates add distilled water only. DO NOT use

tap water with high mineral content, as it will shorten battery life.

• Keep the terminals and tops of the batteries clean.
• Refer to the Service Manual to extend battery life and for complete service instructions.

B

ATTERY

C

HARGING

Figure 7:

Battery Charge Indicator

Charge the batteries at the end of each work shift or
sooner if the batteries have been discharged.

W A R N I N G

!

!

Charge the batteries in a well ventilated area.

Do not charge the batteries when the machine is near a
source of sparks or flames.

Permanent damage to the batteries will result if the
batteries are not immediately recharged after
discharging.

Never leave the battery charger operating for more than two days.

Never disconnect the cables from the batteries when the charger is operating.

Keep the charger dry.

1. Check the battery fluid level. If the battery fluid level is lower than 10 mm (

3

/

8

in.) above the plates add

distilled water only.

2. Connect an appropriate extension cord to charger outlet plug in Right Module Door. Plug the extension

cord into a properly grounded outlet of proper voltage and frequency.

3. The charger turns on automatically after a short delay. The LED charge indicator will illuminate. After

completion of the charge cycle the LED will blink, indicating that the charger is in a continuing
maintenance mode. DO NOT leave the charger plugged in for more than 48 hours, as permanent
damage to the batteries may occur.

NOTE: The battery charger circuit must be used with a GFI (Ground Fault Interrupt) outlet.

NOTE: DO NOT operate the machine while the charger is plugged in.

Battery