Controls and indicators, Pre-operation safety inspection – Snorkel TM12-sn53600-53999 User Manual
Page 9
Page 5
Operation Manual
CONTROLS AND INDICATORS
The operator shall know the location of each control and indicator and have a thorough knowledge of the
function and operation of each before attempting to operate the unit.
Figure 2: Controls and Indicators
Controls and Indicators
PRE-OPERATION SAFETY INSPECTION
NOTE: Carefully read, understand and follow all safety rules, operating instructions, labels and National
Safety Instructions/Requirements. Perform the following steps each day before use.
1. Open the Chassis Door and inspect for damage, fluid leaks or missing parts.
2. Check the level of the hydraulic fluid with the platform fully lowered. Open the Chassis Door and
remove the reservoir cap, fluid should be visible on the dipstick. Add recommended hydraulic fluid if
necessary. See “Specifications” on page 14.
3. Check that the fluid level in the batteries is correct. See “Battery Maintenance” on page 11.
4. Verify that the batteries are charged.
5. Check that the A.C. extension cord has been disconnected from the chassis outlet.
6. Check that all guardrails are in place and all fasteners are properly tightened.
7. Inspect the machine thoroughly for cracked welds and structural damage, loose or missing hardware,
hydraulic leaks, damaged control cable and loose wire connections.
510428-001
510429-001
0
2
1
10
Platform
Controller
Chassis Controller
7
6
5
8
3
4
9
Side View
1. Joystick
2. Emergency Stop
3. Lift / Drive Select
4. Low Battery Indicator
5. Emergency Stop (chassis)
Top View
6. Toggle switch (chassis)
7. Enable button
8. Keyswitch
9. Horn Button
10. BCI / Hour run meter