System Function Inspection

8

SB66JRT

System Function Inspection

Refer to “Controls and Indicators” on page 6 for the loca-

tions of various controls and indicators.

A

Warning

STAND CLEAR of the work platform while performing

the following checks.

Before operating the machine, survey the work area

for surface hazards such as holes, drop-offs, bumps

and debris.

Check in ALL directions, including above the work

platform, for obstructions and electrical conduc-

tors.

1. Move the machine, if necessary, to an unobstructed

area to allow for full elevation.

2. Pull the Lower Control Emergency Stop Switch to the

ON position.

3. Pull the Upper Control Emergency Stop Switch to the

ON position.

4. Visually inspect the elevating assembly, lift cylinder,

cables, and hoses for cracked welds and structural

damage, loose hardware, hydraulic leaks, loose wire

connections, and erratic operation. Check for missing

or loose parts.

5. Test each machine function (Lift, Slew, Telescope)

from the lower control station by holding the ground

operation switch up while operating the control toggle

switches (ref: Figure 3 on page 6).

6. Test the engine/emergency power switch for proper

operation.

7. Push the Lower Control Emergency Stop Button to

check for proper operation. All machine functions

should be disabled. Pull the Lower Control Emer-

gency Stop Button outward to resume.

8. Enter the platform and close the gate.

9. Check that the route is clear of obstacles (persons,

obstructions, debris), is level, and is capable of sup-

porting the wheel loads.

10. Test each machine function (Drive, Lift, Slew, Tele-

scope, Platform Rotate, Platform Level) from the

upper control station by stepping on the platform foot

switch and operating the function controls (ref: Figure

4 on page 6).

11. Push the Upper Control Emergency Stop Button to

check for proper operation. All machine functions

should be disabled. Pull the Upper Control Emer-

gency Stop Button outward to resume.