Connection options for rescue equipment 6 – Lukas LH 2/ 1,8-70 DIN User Manual
Page 9

9
5.2 Adapter blocks
Adapter block
Function/use
Connection plate
with fittings
Possibility of connecting hose
lines directly to the hand
pump
Connection
plate with quick-
disconnect-couplings
Possibility of connecting hose
lines directly to the hand
pump via quick-disconnect-
couplings
Connection plate
with monocouplings
Possibility of connecting hose
lines directly to the hand
pump via monocoupling
Connection options for rescue equipment
6.
ATTENTION!
Make sure to store all plugs, screw plugs and/or dust caps in a way that
prevents them from getting dirty or lost.
After completion of the work, seal off all lines using screw plugs and/or dust
caps to prevent contamination of the hand pump.
When connecting lines to the hand pump, we recommend positioning it
vertically so that the ports point upward. This reduces the danger of hydraulic
fluid escaping.
6.1 Fittings
The hose lines are connected via fittings to the hydraulic pump.
1.
2.
1. First remove the closure caps from
the fittings.
2. Then, you can connect the hose lines
to the fittings and tighten them with a
tightening torque of M
A
= 40 Nm.
ATTENTION!
The return hose must always be connected at the "T" port of the
connection block.
The supply hose line must instead be connected at the "P" port.