Aintenance – MBW WS500 User Manual
Page 10

- 7 -
M
AINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1.
Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
Engine Maintenance
Refer to the engine owner’s manual for maintenance
intervals and procedures.
Engine Speed
The idle speed of the engine should not exceed the
following:
Honda - 3500 rpm
Robin - 2000 rpm
If the idle speed is greater the clutch may not disengage.
Check engine owner’s manual for procedure on setting idle
speed.
Cleaning
Clean any concrete from the ScreeDemon immediately
after each use. DO NOT allow concrete to harden on
the screed.
1.
Use a hose to remove any excess concrete.
2.
Remove any buildup with hard plastic bristle brush.
NOTE: DO NOT use a wire brush, hammer, or pressure
washer to remove concrete from the main unit or
float blade.
3.
Remove the blade.
4.
Start engine and run the exciter for about 10 seconds.
5.
Shut down the engine.
SYSTEM
MAINTENANCE
EACH USE
EVERY 20
HOURS
EVERY 100
HOURS
YEARLY
Engine
Refer to engine operator/owner manual
X
Hardware
Check and tighten as needed
1
X
X
Shockmounts
Check for cracks or tears
X
X