beautypg.com

Initial start procedure, Lock nut – PureFlow AirDog RP-150 - 7.3L Ford 1999-2003 User Manual

Page 14

background image

14

Raptor™ 100 & 150

1999 - 2003 Ford PowerStroke

Section 7 Final Check List

Initial Start Procedure.


7-1.

Turn the starter key to the on/run position.


7-2.

While the Raptor™ Fuel Pump is on, bleed the fuel line to the filter canister by
loosening the fuel line connection at the canister. As soon as the line is purged of air and
fuel is observed, properly tighten the fuel fitting.

NOTE: put a rag or shop towel over

and around the fitting to prevent splatter. Catch all spilled fuel and dispose of properly.


7-3.

Start engine!

Adjusting the Pressure Regulator


To adjust the fuel pressure, loosen the lock nut on the regulator adjustment screw. Using a flat
blade screw driver, rotate the adjustment screw clockwise to increase pressure or counter
clockwise to decrease pressure. Be careful not to loosen the regulator assembly base. If you do,
tighten it immediately. When finished, properly torque the regulator adjustment screw lock nut!

Properly tighten the adjustment screw

Lock Nut

when finished.









Figure 21

RECHECK ALL FUEL FITTINGS FOR LEAKAGE AND PROPERLY TORQUE AS
NECESSARY. BE SURE ALL FUEL LINES ARE PROPERLY ROUTED TO PROTECT
FROM EXCESSIVE HEAT AND SECURED TO PROTECT FROM CHAFFING AND
ABRASION. RECHECK ALL ELECTRICAL LINES, SECURE AS NECESSARY.










This manual is related to the following products: