Figure 20
Installing the Raptor™ Fuel Pump wiring harness.
6-1.
Connect the Power Supply Lead to the Raptor™, by inserting the 2 pin Deutsch
connector on the end of the wiring harness into the corresponding connector on the
Raptor™.
Figure 21
6-2.
Crimp the male spade connector onto the end of the Red (+) wire.
Ground Wire
Hot Lead
Water Resistant Fuse
Raptor™ Pump Lead
Figure 22
Figure 23
Figure 24
6-3.
To connect the positive lead, route the Red (+) wire to the fuse panel located under the
hood on the driver’s side wheel house. Insert the male spade connector into a spare fuse
holder on the fuse panel that is “hot” when the starter key is turned to the on position.
6-4.
Connect the Green (-) wire to an adequate ground.
BE SURE TO PROPERLY ROUTE AND SECURE THE WIRING HARNESS TO THE
VEHICLE.