17
A: Speed (rpm)
B: Can height (cm)
3.2.9
Adjust the mix time
/i
250
200
150
100
SP1
SP2
SP3
SP4
50
0
10
20
30
40
50
A (rpm)
B (cm)
Switch point 3
Switch point 2
Switch point 1
Note
The mix speed depends on the can height.
Key pushed
Mix time [s]
T1
60
T2
120
T3
180
T1 + T2 at the same time
60 + 120 = 180
T1 + T3 at the same time
60 + 180 = 240
T2 + T3 at the same time
120 + 180 = 300