FIG. 11
4. Repeat steps 2 and 3 until water runs clean.
5. Remove the plastic bag. Inspect the cones and
venturi tube to make sure these areas are clean.
6. Return the heater to its original hanging position.
7. Shake the heater vigorously to clear water off of the
combustion cones to allow proper ignition of gas at
the inner cone.
8. Relight the heater to dry out the cones and the
venturi tube.
BB.. FFIILLTTEERR
A. During continued use:
- Remove filter and shake off dust.
- Do not squeeze or tap filter while filter is installed
on heater. Doing so will cause dust to be blown
into venturi tube or combustion cones.
B. After continued use or before building repopulation:
- Remove filter and shake it.
- Use compressed air or standard water faucet
pressure to clean it.
- Do not use high pressure water, air, or a washing
machine. Filter material damage may occur.
- If water is used, squeeze out excess water from
filterbefore installation.
- Let filter dry before lighting heater.
1133
WATER HOSE
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)