Fig. 6 fig. 7, Fig. 8 – L.B. White 350 Premier User Manual
Page 12
C. U
Using IInflatable D
Ducting
CLAMP
DUCT ADAPTER
TABS
DIFFUSER
B. AAttaching EEnd D
Diffuser tto D
Duct
Accessory part 23054
1. Loosen screw on duct clamp so clamp is positioned
over ribs at end of duct.
2. Slide duct adapter into duct end. Duct adapter tabs
must be facing away from duct and are located at 3,
9 and 12 o’clock positions.
See Fig. 5.
3. Tighten screw clamp so adapter is held securely
within duct.
4. Insert tabs of adapter into slots on air diffuser back.
5. Push down on adapter so tabs are seated firmly to air
diffuser.
6. Locate diffuser under side wall. See Fig. 6.
FIG. 6
FIG. 7
TENT DRAPED OVER DIFFUSER
TENT SIDE WALL
TENT DRAPED
WITHIN DIFFUSER
CHANNEL
OPTIONAL AIR DIFFUSER
MATERIAL DRAPED
WITHIN DIFFUSER
CHANNEL
500 GALLON
GAS SUPPLY
(MINIMUM)
MINIMUM SAFE DISTANCE
FROM GAS SUPPLY TO HEATER
IS 6 FEET
TO ALLOW PROPER AIR DISTRIBUTION
FLEXT DUCT MUST NOT HAVE MORE THAN
TWO 90 DEGREE BENDS
MAINTAIN A 10 FOOT CLEARANCE
FROM HEATER TO WALL
DUCT ADAPTER W/ TABS
(FACTORY INSTALLED INTO 12 FT DUCT)
CLAMP
MATERIAL
DRAPED
OVER DUCT
DUCT RING
INFLATABLE DUCT, 100 FT.
DISCHARGE HOLES
POINTED DOWNWARD
(OPTIONAL ACCY 23053)
8 FEET
CLEARANCE
TO GROUND
TYPICAL
CHAIN LOOPED AROUND DUCT
DUCT RING
ROOF SUPPORT
WIRE OR CABLE
(SUPPLIED BY CUSTOMER)
HANGING CLAMP
S-HOOK
CLAMP
FIG. 8
11
10 FEET