Heater specifications, Model – L.B. White HW120 Plus Therma Grow User Manual
Page 4
SPECIFICATIONS
HW120
Propane
Natural
Gas
Gas
Maximum Input (BTUH)
120,000
Minimum Input (BTUH)
65,000
300 CFM
120 sq. in.
64 sq. in.
13.5
11.0
11.0
7.0
5.0
3.1
1.4
0.8
5.56 lbs.
120 cu. ft.
3.01 lbs.
65 cu. ft.
Ball Bearing
1/3 H.P.
1,100 RPM
115/60/1
11.8
4.5
30 3/4 x 21 x 28 1/4
TOP
1 ft.
SIDES
1 ft.
BACK
1 ft.
BLOWER
OUTLET
GAS
Propane Gas Supply — 6 ft. (1.83 m)
SUPPLY
Natural Gas Supply — N/A
(1) Air inlets and exhaust outlets must be electromechanically operated and electrically interlocked with the heater
to prevent heater operation if air inlet and exhaust outlet do not open when heating is required.
Model
Indoor Mounting Air
Exchange Requirements
(1)
Burner Manifold
Pressure (In. W.C.)
Electrical Supply
(Volts/Hz/Phase)
Amp Draw
Dimensions (Inches)
L x W x H
Minimum Safe
Distances From
Nearest
Combustible
Materials
STARTING
CONTINUOUS
OPERATION
Motor Characteristics
Fuel Consumption Per
Hour
Inlet Gas Supply
Pressure Acceptable at
the Inlet of the Heater
for Purpose of Input
Adjustment (In. W.C.)
MAX.
MIN.
MAX.
MIN.
6 ft. (1.83 m)
4
Heater Specifications
Outdoor Mounting Air
Exchange Requirements
(1)
EXHAUST FAN
SHUTTERED AIR INLET
SHUTTERED
EXHAUST OUTLET
MAX.
MIN.