Hanging the heater, Eexhaust fan, Fig. 5 – L.B. White HW120 Plus Therma Grow User Manual
Page 10: Fig. 6
![background image](/manuals/545761/10/background.png)
E
Exhaust Fan
The exhaust fan must be located at an upper area of the
end wall opposite from the heater, preferably in an area
higher than the heater’s discharge. See Fig. 5. The fan
does not need to be directly in line to the heater. Ensure the
exhaust fan is kept free of blockage.
FIG. 5
This heater may be mounted within the greenhouse for
indoor heating applications. The heater may be installed on
an optional indoor mounting bracket kit, part number
23651, which is installed on freestanding supports or
mounted directly to the structure’s wall. Separate
installation instructions accompany the kit.
The heater may also be suspended by chain to the
greenhouse’s overhead structure by using an optional chain
hanging kit, part number 07802. Refer to the following
instructions.and illustrations.
1.
Assemble eyebolts and chain according to the
illustration and tighten all eyebolts securely.
FIG. 6
2.
Ensure the heater is securely fastened to overhead
supports and is hanging level. (Check crosswise and
lengthwise.)
3.
See Fig. 5 for typical indoor installation. In any
installation, consideration must be given to making
sure the heater is located away from the people
entering or exiting the greenhouse so they cannot
accidentally knock the heater or tamper with the
heater and its gas supply line. Additionally, the
heater must be located so that it does not block the
normal entryway or exit of the building. Observe and
obey minimum clearance distances to combustible
materials as stated in the specification section of this
owner’s manual and on the heater’s dataplate.
BYN
ENTRY / EXIT
AIR INLET LOCATED
DIRECTLY BENEATH HEATER
AIR INLET.
AIR
FLOW
EXHAUST FAN IN UPPER
AREA OF GREEN HOUSE
CHAIN OR CABLE
HANGING THE HEATER
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
CHAIN
CASE TOP