background image

15

1. Disconnect heater from its electrical supply.

2. Close fuel supply valves.

3. Remove filter and filter sleeve.

4. Remove the control box cover.

5. Disconnect the igniter lead from ignition module.

6. Loosen the nut on the water tight connection through

which ignition lead is fed. See Fig. 10.

7. Pull the ignition lead through this connection.

8. Pull the boot of the ignition lead up and back from the

igniter along the lead to expose the igniter to ignition

lead connection point. See Fig. 10.

9. Disconnect the high voltage ignition lead.

10. Remove the connector nut from the ignition cable.

This same nut will be slid over the replacement

ignition cable and used to create a water tight

connection at the control box. Tighten the nut

securely.

11. To reassemble, reverse these procedures.

ATTENTION

Before tightening the nut on the water tight

connection, make sure to pull any excess ignition

lead through the water tight connection and into the

control box.

This prevents the lead from coming into contact with

the hot surface of the heater.

DISCONNECT IGNITOR LEAD

FROM CONTROL BOX

LOOSEN NUT

SLIDE BOOT ONLY

LEAVE IGNITOR

CONNECTED

DISCONNECT IGNITER LEAD

FIG. 10

HIGH VOLTAGE IGNITION LEAD