beautypg.com

Hanging instructions sediment trap assembly, Fig. 2, Fig. 3 – L.B. White AW250 User Manual

Page 9: Fig. 4

background image

1. Assemble according to the illustration and tighten all

eyebolts securely. (See Fig. 2):

FIG. 2

2. Be sure heater is securely fastened and is hanging

level. (Check crosswise and lengthwise.) Chain must

be at center of eyebolt for proper heater suspension.

3. See Fig. 3 for typical indoor installation. In any

animal confinement building, consideration must be

given to making sure the heater is located away from

the livestock so that livestock cannot knock the

heater, tear it loose from its mounting, or damage the

heater or its gas supply line in any way. Make sure

you observe and obey minimum clearance distances

to combustible materials as stated in the

specification section of this owner’s manual and on

the heater itself.

FIG. 3

Assemble the tee, nipples and cap together and tighten

securely. See Fig. 4. The sediment trap assembly must

always be mounted in a vertical position. Make sure pipe

thread compound that is resistant to both L.P. gas and

natural gas is used in making all connections.

FIG. 4

9

HANGING INSTRUCTIONS

SEDIMENT TRAP ASSEMBLY

NIPPLE

HOSE ADAPTER

TEE

NIPPLE

CAP

TO GAS CONTROL

VALVE INLET

EYEBOLT

NUT

FLAT WASHER

CAGE NUT

CHAIN

CASE TOP

NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.

VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS

MANUAL SHUT-OFF VALVE
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR
INSIDE THE BUILDING.

OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION

GAS HOSE

THERMOSTAT
CORD

YOKE

HEATER

THERMOSTAT

1 FT.

BLACK PIPE
THROUGH WALL

VENT LINE

WALL OUTLET

POWER CORD

SEDIMENT
TRAP

W

ALL

CHAIN OR CABLE

1 FT.