beautypg.com

L.B. White AW250 User Manual

Page 10

background image

1. To C

Connect tthe S

Series TTap PPlug TThermostat K

Kit:

a. Connect the power cord of the heater to the

female side of the plug on the end of the

thermostat cord.

b. Plug the male side of the series tap plug on the

thermostat cord into a three-wire (grounded)

electrical outlet within the building.

2. To C

Connect tthe D

Direct W

Wired TThermostat K

Kit tto tthe

Control B

Box oon tthe H

Heater:

a. The installation and wiring of a thermostat must

be done by an electrician or someone properly

qualified.

b. The thermostat may use 18 gauge, 2 wire cord to

handle the low voltage being supplied to the

thermostat from the transformer.

c. Follow all instructions provided with the

thermostat kit.

d. The heater must be tested for proper operation

after the thermostat has been connected.

WARNING

Electrical S

Shock H

Hazard

Disconnect the electrical supply before connecting the

thermostat to the heater.

Failure to follow this warning can result in electrical

shock, leading to personal injury or death.

10

THERMOSTAT INSTALLATION

MANUAL SHUT-OFF VALVE, HOSE

AND REGULATOR ASSEMBLY

REGULATOR

NIPPLE

VALVE, MANUAL
SHUT-OFF

GAS HOSE

ADAPTER

SEDIMENT TRAP

TO CONTROL

VALVE INLET

REGULATOR VENT

GAS FLO

W

1. Always use approved pipe thread compound suitable

for use with L.P. gas or natural gas on the threaded

connections.

2. Assemble the components together according to the

figure. This view is to show general assembly of the

components only. The regulator must always be

mounted so its vent, regardless of location on the

regulator, is always pointed downward.

3. Tighten all connections securely.

FIG. 5