Owner’s Manual
Compressor (cont’d)
TROUBLESHOOTING (cont’d)
Excessive starting and stopping, while not in use
• Fittings leak
 Check fittings with soapy water. Tighten or reseal leaking fittings. DO NOT
 OVERTIGHTEN.
 Replace worn parts and reassemble with new seals.
 Replace any regulator internal parts.
• Regulated pressure gauge reading drops when air accessory is being used.
 This is normal in some applications
 Compressor not large enough.
 If pressure drops too low, adjust regulator while accessory is used.
 Check air requirement of accessory, it may be higher than CFM pressure supplied by
 compressor. Most accessories are rated at 25% of actual CFM while running
 continuously.
Circuit breaker trips (fuse blows) too often
• Low voltage
 Consult electrician.
• Excessive wire length
 Furnish adequate power .If using extension cord, try again without it.
• Restricted air passages
 Contact authorized service center.
• Back pressure in pump head
 Replace check valve.