beautypg.com

6 testing & final assembly, Filling the differential – ARB RD05 User Manual

Page 35

background image

6 Testing & Final Assembly

33

Turn the ignition to the ‘ON’ position (leaving the motor off). The

large illuminating symbol on the Air Locker switch cover should be
‘OFF’.

Turn the compressor (or alternate air source) on to charge the air

supply up to its maximum pressure.

Rotate one wheel by hand.
The wheel should rotate freely and the opposite wheel should be

turning in the opposite direction without any resistance or
mechanical noise from within the differential.

Turn the Air Locker switch to the ‘ON’ position. The illuminated

symbol on the switch cover should light up.

Rotate the same wheel again.
Both wheels should rotate together.
Turn the switch off again.
Rotate the same wheel.
The wheels should again rotate in opposite directions.

6.3

Filling the Differential

NOTE : Consult the ARB Air Locker Operating & Service

Manual for recommendations on differential lubricant
specifications.

Refill the differential until level with the filler hole.
Rotate the differential center 2 full turns.
Check the oil level and add oil if necessary.
Apply thread sealant to filler plug before inserting.
Replace the filler plug.
Clean the differential housing of any oil or grease that may collect

dirt or other abrasive particles.