TROUBLESHOOTING SUGGESTIONS

SUGGESTED REMEDY

Check power supply cord
Check / reset circuit breaker


Set for desired temperature


Allow to cool hi-limit will self-
reset


Examine wiring & connectors,
controller, water level probe and
heating element
Repair/replace as needed


Program volume keys


Use one (1) genuine Bloomfield
filter per brew


Thoroughly clean brew
chamber


Use correct grind and amount
of coffee


Program vol. key for pulse brew


Check/reinstall gasket on
INSIDE of brew head


Clean spray disk


Check keypad, controller, and
pump
Repair, replace as needed


Turn water supply ON


Clean strainer


Replace filter element


Check controller and water level
probe


Check solenoid and switch
Repair/replace as needed

POSSIBLE CAUSE

Brewer unplugged or circuit
breaker tripped


Temperature setpoint too low


Hi-Limit safety switch tripped


Damaged internal component
or wiring


Volume keys not programmed


Too many filter papers or wrong
filter paper


Brew chamber dispense hole
plugged


Too much coffee or too fine a
grind


Not using pulse brew feature


Spray gasket improperly
installed


Spray disk plugged


Damaged internal component
or wiring



Water supply OFF


Solenoid inlet strainer plugged


Water filter (if used) plugged


Damaged internal component
or wiring


Damaged internal component
or wiring

SYMPTOM

Water won’t heat









Coffee level too high or low


Brew chamber overflows







Sprays water from brew head



No brew (faucet flows OK)




No brew plus no flow from hot
water faucet






No flow from hot water faucet
(brew OK)

Poor coffee quality

Keep brewer and airpots clean.
Install optional taste and odor filter, and replace cartridges
regularly.
Use a quality coffee with a consistent roast. Use proper grind
and amount of coffee per brew.