SERVICE (cont.)

LIMIT THERMOSTAT

FIG. 4 LIMIT THERMOSTAT

P1798.40

Location:

The limit thermostat is located inside the hood on

the tank lid.

Test Procedure:
1. Disconnect the brewer from the power source and

remove the blue wire from the limit thermostat.

2. With a voltmeter, check the voltage across the blue

wire removed from the limit thermostat and the
white wire on the tank heater terminal. Connect
the brewer to the power source. The indication
must be 120 volts ac for two wire120 volt mod-
els.

3. Disconnect the brewer to from the power source.

If voltage is present as described, reconnect the blue
wire and proceed to #4.
If voltage is not present as described, refer to the

Wir-

ing Diagrams

and check the wiring harness.

4. Remove the black wire from the limit thermostat.

5. With a voltmeter, check the voltage across the ex-

posed terminal of the limit thermostat and the
white wire on the tank heater terminal. Connect
the brewer to the power source. The indication
must be 120 volts ac for two wire 120 volt mod-
els.

6. Disconnect the brewer from the power source.

If voltage is present as described, reconnect the black
wire to the limit thermostat. The limit thermostat is
operating properly.
If voltage is not present as described, replace the limit
thermostat.

Removal and Replacement
1. Remove both wires from the limit thermostat ter-

minals.

2. Carefully slide the limit thermostat out from un-

der the retaining clip.

3. Carefully slide the new limit thermostat into the

retaining clip.

4. Refer to Fig. 5 when reconnecting the wires.

BLU to Control
Board N.O.

BLK to Tank Heater

FIG. 5 LIMIT THERMOSTAT TERMINALS

P1800