DIAGNOSTICS

Intermittent flashing of the READY indicator indicates that a fault exists. Count the number of flashes between
pauses and use this chart as a guide to investigating the fault.

FLASHES CAUSE

THINGS TO CHECK

1

Dry Plug - In Fault -

Water Pressure (Is water shut off?)

Sheath of temperature probe dry for 10 minutes after power-up

Temperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board

2

Low Tank Level Fault -

Water pressure (Is water shut off?)

Level probe dry for 7 minutes after fill valve is energized

Shorting pin on J6 connector of control board
not on correct set of pins (See page 7)
Level probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer

3

Low Water Temperature Fault -

Tank heater wiring & function

Sensor in tank is calling for heat for 30 minutes or more

Temperature probe wiring

4

Tank Sensor Disagreement -

Temperature probe wiring

Level probe detects water, but dry plug-in probe dry

Level probe wiring
Green wire between tank and circuit board

5

Temp Sensor Out-of-Range - High

Sensor not connected to circuit board

6

Temp Sensor Out-of-Range - Low

Sensor wires shorted together or to chassis