beautypg.com

Cont.) – Black Box MDR210A-485 User Manual

Page 12

background image

12


Application Notes

(cont.)


Range

Received

Detectable by

Detectable

by

(meters)

Power

MDR210A-485 Commercial

Radio

100

-68.526 dBm

YES

YES

500

-82.506 dBm

YES

YES

1000

-88.526 dBm

YES

YES

3000

-92.048 dBm

YES

NO

5000

-102.506 dBm

YES

NO

8000

-106.588 dBm

YES

NO

10000

-108.526 dBm

YES

NO

11265

(7miles) -109.559 dBm

YES

NO

12000

-110.805 dBm

NO

NO


Since the range doubles every 6dB, the 20dB sensitivity difference in radios corresponds
to 2^(20/6) = 10.08 times the range using the MDR210A-485 radio!