14

• Do not pre-twist the wires before connecting them

with wire nuts.

• Extend the dishwasher’s stranded wires 1/8” (3mm)

beyond the power supply cable’s solid wires, as
shown in Figure 29.

5 Using the supplied wire nuts, connect the electrical

supply wires to the dishwasher’s wires, black to black,
white to white, and green or bare. Make certain that
the insulated wires show no bare wire from the
bottoms of the wire nuts. Gently tug the wires to make
certain they are securely connected.

6 Press the wires into the junction box. Make certain

that the wire nuts do not loosen.

7 Place the cover on the junction box and secure it to

the junction box with the supplied screw.

DOOR TENSION ADJUSTMENT (only on SHI
and SHV models with custom door panels)

After the dishwasher and custom door panel are installed,
open and close the door several times to make sure that
it does so with ease. If the door closes too quickly, the
spring tension needs to be adjusted.

To Adjust the Spring Tension:
1
Obtain the provided Spring Tension Screws from the

SHI/SHV Door Panel Installation Kit.

2 Insert the screws as shown in Figure 30. Turning the

screw clockwise increases the spring tension.

TOE PANEL INSTALLATION

Regular Toe Panel Installation
Use the toe panel screws from the Dishwasher Installa-
tion Kit and a Torx screwdriver to install the toe panel as
shown in Figure 31.

Figure 29

ELECTRICAL CONNECTION (continued)

Figure 30

Figure 31

1/8”
3mm

Electrical Connection/ Door Tension Adjustment/ Base and Toe Panel

Fire Hazard

To avoid a fire hazard, make sure there are no
loose electrical connections. Make sure all
electrical connections are properly made.

WARNING