beautypg.com

Bosch 9000060331 (8503) User Manual

Page 10

background image

8

DISHWASHER PREPARATION (continued)

Removing the Toe Panel
Regular Toe Panel
The toe panel is loosely attached with tape. Remove the
tape and pull the toe panel away from the dishwasher. Set
the toe panel aside. It will be reinstalled later.

Plastic Base Access Panel and Toe Panel (SHY66C,
SHX99A, SHE66C, SHE99C, SHX57C, and SHV57C
models only)
The plastic base access panel and toe panel are in place
on the dishwasher, but are not attached. Remove the toe
panel first, as shown in Figure 11, then remove the
plastic base access panel, as shown in Figure 11.

Installing the 90° Elbow Fitting
NOTE:
The 90° elbow fitting is not supplied with the
dishwasher, and must be purchased separately. If the
dishwasher’s hot water supply line is to be copper tubing,
make certain the elbow has a compression fitting.
Apply Teflon tape or other pipe sealant when required.
Orient the hot water supply connection leg of the elbow
toward the channel opening in the dishwasher base. See
Figure 12.

Junction Box Preparation

1

Remove junction box cover (see Figure 13) by lifting
the junction box cover up and off.

2

Remove the strain relief plate by removing the screw
at the back of the junction box, as shown in Figure
14
and sliding the strain relief plate out.

3

Set the junction box cover, strain relief plate, and
screw aside. They will be re-installed later.

Figure 11

Toe

Panel

Plastic Base

Access Panel

Dishwasher Preparation

Figure 13

Figure 14

X

Remove Screw

Figure 12

Junction

Box

Cover