Chapter 5: Troubleshooting

Frequent loss of

ADSL linesync

(disconnections).

Ensure that all other devices connected to the same telephone line as your

Billion router (e.g. telephones, fax machines, analogue modems) have a

line filter connected between them and the wall socket (unless you are

using a Central Splitter or Central Filter installed by a qualified and

licensed electrician), and ensure that all line filters are correctly installed

and the right way around. Missing line filters or line filters installed the

wrong way around can cause problems with your ADSL connection,

including causing frequent disconnections.

Problems with the LAN Interface

Problem

Corrective Action

Can’t ping any PCs on

the LAN.

Check the Ethernet LEDs on the front panel. The LED should be on for a

port that has a PC connected. If it is off, check the cables between your

router and the PC. Make sure you have uninstalled any software firewall

for troubleshooting.

Verify that the IP address and the subnet mask are consistent between the

router and the workstations.

Problems with the Trend Micro Security Service

Problem

Corrective Action

Can’t view the heath

check report.

Check your Internet Explorer version. You must upgrade it to version 5.5

or above

My PC health Check

result does not report

correctly.

Check your network topology. Make sure your router is direct connected to

your PCs.

ADSL

myGuard Router

router 2

PCs

ADSL

router 1

myGuard Router

PCs

My ActiveX shows as

expired components

Check your Internet Explorer version. You must upgrade it to version 5.5

or above.