13. Set tank assembly inside the hood on mounting
brackets and secure with two #8-32 screws.
14. Reconnect the wires to the limit thermostat, tank
heater and the control thermostat. Refer to
Limit
Thermostat, Tank Heater
and
Control Thermostat
sections in this manual when reconnecting wires.
15. Secure the sprayhead tube to the hood using hex
nut.
16. Install sprayhead.
17. Install fill basin, inlet gasket and secure to tank lid
with tank inlet fitting.
18. Refer to Fig. 11 when reconnecting the wires.
Removal and Replacement: (VP17B)
1. Remove the tank inlet fitting securing fill basin to
the tank lid. Remove fill basin and gasket. Set all
three parts aside for reassembly.
2. Disconnect the two black wires from the tank
heater switch.
3. Remove the plastic facenut, hex facenut and the
switch indicator/guard bracket that secures tank
heater switch to the brewer. Remove switch and
discard.
4. Insert new tank heater switch through the hole in
the lower left of the control panel and secure with
swtich indicator/guard bracket, hex facenut and
plastic facenut.
5. Reconnect the two black wires the to the tank
heater switch terminals.
6. Install fill basin, inlet gasket and secure to tank lid
with tank inlet fitting.
7. Refer to Fig. 11 when reconnecting the wires.
TANK HEATER SWITCH (cont.)
P1135
FIG. 11 TANK HEATER SWITCH TERMINALS
10860 090800
BLK to Limit
Thermostat
BLK to Terminal
Block (Black Insert)