System Programming
The system programming is compatible with both the LCD transmitter or the standard AM transmitter.
Enter System Programming:
1. Turn on ignition.
2. Within 5 seconds, press the valet switch 5 times.
· The horn will provide three chirps, indicating that you have entered Programming.
3. Press the valet switch the number times equal to the System Parameter you want to change.
· The horn will chirp each time the valet switch is pressed.
4. Within 5 seconds, press the transmitter button corresponding to the desired operating mode for
that System Parameter.
· The horn will chirp to indicate the setting.
1 chirp = Button 1
2 chirps = Button 2
3 chirps = Button 3
5. When you are finished, turn off the ignition to save the changes.
Default Reset
Following this procedure will set all System Programming Parameters to factory default settings.
1. Enter System Programming.
2. Press Transmitter Button 3.
· The horn will chirp 6 times indicating that the reset signal was received.
· All System Programming parameters are now set to factory default settings.
· The Valet Mode is off.
3. Turn off ignition.
Programmable System Options
The following is a description of the programming options of the system. Some of the program branches control more
than one option, and may require accessing a particular branch number twice in order to program all desired fea-
tures.
3. Lock/Unlock Chirps. Selects between normal and silent operation.
5. Extended Parking Lights. When Enabled, upon Disarming Parking lights will turn On for 30 seconds or until the
Dome light turns Off
Reset Mobilink (Galaxy Mobile) module.
6. Ignition Door Locking / Valet Code Set. This dual program branch selects Ignition Door Locking, and programs the
optional Emergency Valet Code. Ignition Door Locking. Selects whether or not the system will automatically lock the
doors 5 seconds after the ignition key is turned on. Valet Code Set. Changes the Emergency Valet Code for a higher
level of security.
7. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is
turned off.
8. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output. Many new import
vehicles’ factory door locking systems require two pulses on the proper wire to unlock the doors. These systems can
be interfaced directly without the use of relays or any additional circuitry by programming the system for double un-
lock pulse. also programs to pulse the ignition before unlock
9. Door Lock Pulse Length. Selects between a 1-second, 3-second or 0.1 second output for door locking and unlocking.
Program to 3 seconds for vehicles equipped with vacuum door locking systems. 0.1 seconds for vehicles that roll
windows up or down when lock/unlock output is at 1 second.