Alpine specifications alpine dimensions, Alpine intake / vent sizes, Maximum vent lengths – Burnham Condensing Stainless Steel User Manual

Page 4

background image

© 2008 U.S. Boiler Company, Inc. - Lancaster, PA

Phone: 1-888-432-8887

www.burnham.com

Printed in the U.S.A.

Pub. HYDL04081-25Ms

www.burnham.com

Alpine

16-11/16”

A

L

Low Voltage
Knockouts (24V)

Line Voltage
Knockouts (115V)

One handle on
ALP80 & 105, Two
handles on all
other models

G

(Return tapping)

F

(Gas valve inlet)

H

(Supply tapping)

3/4” FPT
relief/drain
tapping

J

(Condensate

trap drain)

M

N

O

P

D

C

E

B

Q

Model

No.

A

(in.)

B

(in.)

C

(in.)

D

(in.)

E

(in.)

F

(in.)

G

(in.)

H

(in.)

J

(in.)

L

(in.)

M

(in.)

O

(in.)

P

(in.)

Q

(in.)

ALP080

12-9/16

5-5/8

7-5/16

9-5/16

5-15/16

1/2

1

1

*

8

32-3/16

16-11/16

12-1/2

4-3/4

ALP105

14

5-13/16

7-5/16

10-3/4

5-15/16

1/2

1

1

*

8

32-3/16

16-11/16

12-1/2

4-3/4

ALP150

19-11/16

5-13/16

7-5/16

16-7/16

5-15/16

1/2

1

1

*

8

32-3/16

16-11/16

12-1/2

4-3/4

ALP210

23-15/16

5-13/16

7-5/16

17-1/8

5-15/16

1/2

1

1

*

8

32-3/16

16-11/16

12-1/2

4-3/4

ALP285

21-13/16

7-5/16

14-1/8

18

12-1/4

3/4

1-1/4

1-1/4

*

8-5/16

43-7/16

17-5/16

12-3/16

4-3/4

ALP399

28-7/8

6-3/16

13-1/16

23-3/4

15-13/16

1

1-1/2

1-1/2

*

8-5/16

43-7/16

17-5/16

12-3/16

4-3/4

*Factory provided socket end compression pipe joining clamp for 3/4” schedule 40 PVC pipe

Model No.

Input (MBH)

Output

(MBH)

Net

I=B=R
(MBH)

AFUE

(%)

Boiler Water

Volume

(gallons)

Heat Trans.

Area

(sq. ft.)

Shipping

Weight

(pounds)

Minimum

Maximum

to 2k ft.

2-7k ft.

0-7k ft.

ALP080

16

27

80

73

63

95

0.6

0.6

137

ALP105

21

35

105

96

83

95

0.7

0.7

155

ALP150

30

50

150

137

119

95

1.3

1.3

182

ALP210

42

70

210

193

168

95

1.7

1.7

206

ALP285

57

57

285

263

229

95

2.4

2.4

256

ALP399

80

80

399

377*

328

94.1/94.5**

3.4

3.4

304

ALP500

– Call for product availability and additional information –

Alpine Specifications

Alpine Dimensions

NOTES: DOE Heating Capacity (ALP080 through ALP285); Gross Output (ALP399)

Maximum Working Pressure - Water: ALP080-285=30PSI; ALP399=50PSI; 80PSI optional on all models

Maximum Allowable Temperature = 210˚ F

Boilers shipped set for natural gas; field adjustment for LP (see instruction manual)

For elevations above 2000 feet, reduce ratings four percent (4%) per 1000 feet above sea level

Model

No.

Intake

Size

Vent

Size

Max

Length

ALP080

3”

3”

60’

ALP105

3”

3’

60’

ALP150

4”

3”

60’

ALP210

4”

3”

60’

ALP285

4”

4”

60’

ALP399

4”

4”

60’

Alpine Intake / Vent Sizes

Max length in equivalent feet for each run is 60

equivalent feet of intake & 60 equivalent feet

vent length

# of 90° Elbows

2

4

6

8

10

12

Combined Intake/Vent - Feet of Pipe

110’

100’

90’

80’

70’

60’

Maximum Vent Lengths

NOTE: Snorkels are approved for use with PVC venting.

Intake & vent lengths combined. 90° = 5 equivalent feet.

Terminals do not count towards vent feet length

** Thermal/combustion efficiency

*Gross output